In the industry, it is widely used in semiconductors, raw materials, integrated chips, LED brackets, PCBs, precision components and other materials, finished products, semi-finished products, moisture-proof and anti-oxidation storage.
In the process of using the intelligent moisture-proof cabinet, it is unavoidable that the fault is generated. The intelligent moisture-proof cabinet is used earlier because of its earlier origin.
So, what are the main faults of the intelligent moisture-proof cabinet? What should I do when I encounter it?
Common faults of intelligent moisture-proof cabinets (also called moisture-proof boxes, drying boxes, drying cabinets) include: humidity does not drop, humidity decreases slowly, humidity display is not accurate, humidity is not displayed, and cabinet is damaged.
The problem of not degrading humidity or slowing down is mainly the problem of dehumidifying parts. In this case, first check if there is a problem with the humidity display, which leads us to mistakenly believe that the humidity of the moisture-proof cabinet does not drop or fall slowly.
The second is to check the movement valve at the rear of the moisture-proof cabinet to see if the valve cannot be normally opened and closed due to the jamming of small objects.
Furthermore, it is to check whether the movement has no heat when the light is on. If there are these problems, in addition to the valve stuck, it can be handled by ordinary engineers, and others need to be processed by the manufacturer.
If the above problems do not occur, and the moisture-proof cabinet still does not drop or slow down, it may be that the core molecular sieve material is aging, and the entire upper core needs to be replaced.
If the humidity of the intelligent moisture-proof cabinet is not displayed or the display is inaccurate, the fault may be caused by the failure of the meter sensor or the calibration of the sensor. Allows the manufacturer to calibrate or replace the meter controller.
If the cabinet is damaged, it is necessary to check the sealing of the intelligent moisture-proof cabinet. If the sealing of the moisture-proof box itself is not affected, the damage of the drying cabinet may not be repaired. However, if the sealing is affected, it is necessary to consider the maintenance of the moisture-proof cabinet manufacturer or replace the entire moisture-proof cabinet.